11.4 Back up hard disk via Norton GhostR (SW 4.4 and higher)
11-265
Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) 04.00 Edition
11.4 Back up hard disk via Norton Ghost
R
(SW 4.4 and
higher)
11.4.1 Back up hard disk / Import data backup
S Simple backup and restoration of MMC102/103 hard disks on site.
System software, add-on software and user-specific data blocks are backed
up completely.
S A hard disk image (saved in a file) can be backed up on a data medium
(e.g. CD) for long-term storage and safekeeping.
S Master images (images for series start-up) can be loaded by the machine
manufacturer.
S Machine manufacturers can perform upgrades/downgrades (master images)
themselves, irrespective of software supplied by Siemens.
S The Norton Ghost
R
backup program is installed on every MMC102/103 with
SW 4.4 and higher.
The Norton Ghost
R
software allows the complete contents of an MMC102/103
hard disk to be saved as a disk image. This image can be safely stored on
various types of data medium for the purpose of restoring the hard disk at a
later time. The Norton Ghost
R
program is supplied as standard with every
MMC102/103 module.
For further information, visit the Internet site at www.ghost.com.
The procedure for saving a complete MMC 102/103 hard disk for the purpose of
having all user and system data continually available during servicing is de-
scribed below:
a) Backing up the hard disk
b) Backing up the user data
c) Restoring a backup of the hard disk
for running the Norton Ghost
R
program
You need a keyboard with a PS/2 connector
in order to access and modify the BIOS (a PG keyboard is also suitable).
MMC BIOS versions up to 2.14 are accessed by
pressing CTRLALTESC; BIOS versions 3.04 and higher
by pressing DEL during MMC power-up.
You can undo BIOS settings by loading the
BIOS Setup Defaults.
With the MMC 102 you must change the BIOS setting to
Virus Warning: Disabled
for a hard disk restore; the setting does not need to be changed for a backup.
Functions
Norton Ghost
R
MMC 102/103
Operating tips
MMC BIOS
MMC 102
11 Data Backup
04.00

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals