EasyManuals Logo

Siemens SINUMERIK 810D Installation And Startup Guide

Siemens SINUMERIK 810D
327 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #267 background imageLoading...
Page #267 background image
11
03.96
11.4 Back up hard disk via Norton GhostR (SW 4.4 and higher)
11-267
Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) 04.00 Edition
1. A backup/restore at file level is performed on the MMC in the Services area,
e.g. by selective backup of start-up or machine data, etc. (via diskette, V.24,
PC card).
2. Individual software components are installed/re-installed either via diskette
or parallel interface (Interlnk/ InterSrv).
Problems associated with the BIOS update must be considered.
3. With MMC102/3 running BIOS Version 2.12 the error Expection error (13)
can occur after a successful restore.
Remedy: Switch the MMC102/103 off and on again.
4. For a backup/restore via parallel port or network the power saving feature of
the PC/PG must be deactivated.
5. After completing the backup/restore with Ghost, the parallel cable should be
removed again, in order to prevent unexpected MMC operating states.
6. If the external PC is equipped with an AMD K6 processor, problems can
arise with the parallel connection at processor clock speeds > 233 MHz. In
this case, operate both computers (MMC and PC) with LPT BIOS setting
ECP.
7. CDROM drive access problems can occur occasionally with certain pro-
gramming devices. This can lead to a shut-down of the Ghost connection
during the direct restore of an image file from CDROM.
Remedy: Copy the image file from the CD onto the hard disk of the program-
ming device.
S Storage of complete hard disks in an image file
S Restoration of hard disks from an image file
S Compression of image files
S Integrated link via LPT master/slave interface, e.g. from
MMC 103 with PG (without Interlnk/ Intersrv)
S Support for different operating systems of the MMC102/103 with SW 3.x and
SW 4.x:
Windows 3. x
Windows 95
S Support of long file names
S Disk integrity and image file integrity check
S Reloading of image files to unformatted hard disk (formats on the fly)
S New destination hard disk can be larger or smaller (provided it is sufficient
for data quantity) than the original
Supplementary
conditions
Functions of
Norton Ghost
R
11 Data Backup
12.98

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals