EasyManuals Logo

Siemens SINUMERIK 810D Installation And Startup Guide

Siemens SINUMERIK 810D
327 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
3
03.96
3.3 Connection of a 2nd MCP/customer OPI and/or 1 HHU (up to SW 3.1)
3-51
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
The SDB 210s have been generated during compilation. Transfer SDB 210 for
CPU program as314 to the PLC–CPU (PLC must be in the STOP state).
Procedure:
1. Click on File/Download to PLC menu
2. Download window appears. Select as314//CPU1:: and confirm with OK.
3. Switch PLC into RUN mode (restart).
The default address 15 can be left unchanged on the HHU, only the GD param-
eters at 1.1.1–1.2.1 must be set, see Section 3.4.
The following parameter settings must be added to FB1 for the HHU.
.
.
.
HHU:=1 (HHU on MPI bus)
BHGIn:=P#M20.0 (HHU input signals)
BHGOut:=P#M0.0 (HHU output signals)
BHGStatRec:=P#M26.0 (status double word)
.
.
.
The other HHU parameters are set to appropriate defaults.
SDB210
Set HHU
Parameterization
of basic PLC
program FB1
3 Settin
g
s, MPI / OPI

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals