3.6 Machine control panel (MCP)
3-67
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
Table 3-8 Meaning of switch S3 for machine control panel
1 2 3 4 5 6 7 8 Meaning:
on
off
Baud rate: 1.5 Mbaud
Baud rate: 187.5 kbaud
on
off
off
off
on
off
200ms cycle transmit pattern / 2400 ms receive monitoring
100ms cycle transmit pattern / 1200 ms receive monitoring
50 ms cycle transmit pattern / 600 ms receive monitoring
on
on
on
on
on
on
on
on
off
off
off
off
off
off
off
off
on
on
on
on
off
off
off
off
on
on
on
on
off
off
off
off
on
on
off
off
on
on
off
off
on
on
off
off
on
on
off
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
on
off
Bus address: 15
Bus address: 14
Bus address: 13
Bus address: 12
Bus address: 11
Bus address: 10
Bus address: 9
Bus address: 8
Bus address: 7
Bus address: 6
Bus address: 5
Bus address: 4
Bus address: 3
Bus address: 2
Bus address: 1
Bus address: 0
on Interface to customer operator panel
off MCP
on off on off on on off off Default setting
on off on off on on off off Default setting for 840D
Baud rate: 1.5 Mbaud
Cyclical transmit pattern: 100 ms
Bus address: 6
Switch S3
3 Settin
g
s, MPI / OPI
08.9705.97

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals