Detailed description
2.12 Block descriptions
Basic logic functions: PLC basic program solution line (P3 sl)
184 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Description of formal parameters
The table below lists all formal parameters of the TM_REV function.
Signal Typ
e
Type Value range Remark
Start I BOOL 1 = Start of transfer
ChgdRevNo I BYTE 1.. Number of revolver interface
Ready A BOOL 1 = Transfer complete
Error A INT 0..3 Error checkback
0 : No error has occurred
1: No revolver present
2: Illegal revolver number in parameter "ChgdRevNo"
3: Illegal job ("interface active" signal for selected
revolver = "FALSE")
Pulse diagram
5HDG\
6WDUW
(UURU !








(1) Activation of function by means of a positive edge
(2) Positive acknowledgment: Tool management has been transferred
(3) Reset function activation after receipt of acknowledgment
(4) Signal change using FC
(5) This signal chart is not permissible. The job must generally be terminated since the new tool
positions must be conveyed to the tool management in the NCK.
(6) Negative acknowledgment: Error has occurred, error code in the output parameter "Error".

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals