EasyManuals Logo

Siemens SINUMERIK 810D Function Manual

Siemens SINUMERIK 810D
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
Detailed description
2.2 Functions
Basic logic functions: Various NC/PLC interface signals and functions (A2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
37
Reading in part program
Program code (extract) Comment
. . .
PLCDATA = $A_DBW[4];
// Read a word
. . .
Behavior during POWER ON, block search
The DPR communications buffer is initialized during "POWER ON".
During a "block search", the PLC variable outputs are collected and transferred to the DPR
communications buffer with the approach block (analogous to writing of analog and digital
outputs).
Other status transitions have no effect in this respect.
2.2.5 Access protection via password and keyswitch
2.2.5.1 Access protection via password and keyswitch
Access authorization
Access to functions, programs and data is useroriented and controlled via 8 hierarchical
protection levels. These are subdivided into:
Password levels for Siemens, machine manufacturer and end user
Keyswitch positions for end user

Table of Contents