Detailed description
2.11 Response to overstore
Basic logic functions: Auxiliary Function Output to PLC (H2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
45
2.11 Response to overstore
Overstore
Before the start, on the SINUMERIK operator interface, the following functions:
NC START of a part program
NC START to resume an interrupted part program
the auxiliary functions that are output at the start can be changed by the "Overstore"
function.
Possible applications include:
Addition of auxiliary functions after block search
Restoring the initial state to position a part program
Types of auxiliary functions that can be overstored
The following types of auxiliary functions can be overstored:
M (special function)
S (spindle speed)
T (tool number)
H (aux. function)
D (tool offset number)
DL (additive tool offset)
F (feed)
Duration of validity
An overstored auxiliary function, e.g. M3 (spindle right), is valid until it is overwritten by
another auxiliary function from the same auxiliary function group, by additional overstoring or
by programming in a part program block.

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals