Detailed description
2.4 Frames
Basic logic functions: Axes, coordinate systems, frames (K2)
130 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
2.4.12.3 RESET, end of part program
RESET responses of basic frames
The RESET response of basic frames is set via the machine data:
MD20110 $MC_RESET_MODE_MASK (definition of initial control settings after RESET/TP-
End)
RESET responses of system frames
The system frames are retained in the data management after a Reset.
The machine data below can be used to configure the activation of individual system frames:
MD24006 $MC_CHSFRAME_RESET_MASK (active system frames after Reset)
Bit Significance
0 System frame for actual value setting and scratching is active after RESET.
1 System frame for zero offset external is active after RESET.
2 Is not evaluated.
3 Is not evaluated.
4 System frame for workpiece reference point is active after RESET.
5 System frame for cycles is active after RESET.
6 Reserved, RESET response depends on MD20110 $MC_RESET_MODE_MASK.
7 System frame $P_ISO1FR is active after RESET.
8 System frame $P_ISO2FR is active after RESET.
9 System frame $P_ISO3FR is active after RESET.
10 System frame $P_ISO4FR is active after RESET.

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals