EasyManuals Logo

Siemens SINUMERIK 810D Function Manual

Siemens SINUMERIK 810D
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1637 background imageLoading...
Page #1637 background image
Detailed Description
2.1 Spindle modes
Basic logic functions: Spindles (S1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
27
Phase 4, 4a
The spindle is stationary and has reached the end point. Position control is active and holds
the spindle in the programmed position.
NC/PLC IS:
DB31, ... DBX60.6 (Position reached with exact stop coarse)
and
DB31, ... DBX60.7 (Position reached with exact stop fine)
are set if the distance between the spindle actual position and the programmed position
(spindle setpoint position) is less than the settings for the exact stop fine and coarse limits.
This is defined in machine data:
MD36010 $MA_STOP_LIMIT_FINE
and
MD36000 $MA_STOP_LIMIT_COARSE.
Phase 3:
At the point, which is determined by the braking start point in Phase 2,
the spindle decelerates to standstill with the acceleration from the following machine data:
MD35210 $MA_GEAR_STEP_ POSCTRL_ACCEL
Phase 4:
The spindle is stationary and has reached the end point. Position control is active and holds
the spindle in the programmed position.
NC/PLC IS:
DB31, ... DBX60.6 (Position reached with exact stop coarse)
and
DB31, ... DBX60.7 (Position reached with exact stop fine)
are set if the distance between the spindle actual position and the programmed position
(spindle setpoint position) is less than the settings for the exact stop fine and coarse limits.
This is defined in machine data:
MD36010 $MA_STOP_LIMIT_FINE
and
MD36000 $MA_STOP_LIMIT_COARSE.
Aborting the positioning process
The positioning action can only be aborted with NC/PLC IS:
DB31, ... DBX2.2 (Delete distancetogo/Spindle reset).
The positioning action is aborted with each reset (Operator panel front reset / NC/PLC IS
DB31, ... DBX2.2 (Delete distancetogo/Spindle reset)),
independent of machine data:
MD35040 $MA_SPIND_ACTIVE_AFTER_RESET (individual spindle reset).

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals