EasyManua.ls Logo

Siemens SINUMERIK 810D

Siemens SINUMERIK 810D
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Detailed Description
2.1 Spindle modes
Basic logic functions: Spindles (S1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
31
Table 2-2 Switch back to spindle mode
C=...
M71
→ Output to PLC
Closed-loop controller enable off (by PLC)
Switch actuator (by PLC)
Switched to spindle parameter set (1-5) internally in the NC,
controller enable on (by PLC)
M3/4/5
or
SPOS=...
NC travels with spindle parameter set
Change to spindle mode
The interpolation parameter (set 1 ... 5) is selected according to the currently valid gear step.
The feedforward control function is always activated, except for tapping with compensating
chuck.
Machine data:
MD32620 $MA_FFW_MODE (feedforward control type)
must always be not equal to 0.
Feedforward control should always be operated with the value 100% to avoid alarms being
output during positioning.






$[LVPRGH 6SLQGOHPRGH
'HSHQGLQJRQJHDUVWHS
3DUDPHWHUVHW
9DOLG
9DOLG
9DOLG
9DOLG
9DOLG
9DOLG
Figure 2-4 Validity of parameter sets for axis and spindle modes