EasyManuals Logo

Siemens SINUMERIK 810D Function Manual

Siemens SINUMERIK 810D
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1754 background imageLoading...
Page #1754 background image
Detailed description
2.3 Feedrate control
Basic logic functions: Feeds (V1)
38 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Spindle override" DB31, ...DBB0"
One enable signal and one byte is provided on the PLC interface for the override factor for
each of the spindles.
IS "Spindle override" (DB31, ... DBB19)
IS "Override active" (DB31, ... DBX1.7)
The interface for the spindle override can be provided by the PLC in binarycoded or Gray-
coded format.
Machine data:
MD12060 OVR_SPIND_IS_GRAY_CODE (spindle override switch is Graycoded)
is used to define whether binary or Gray coding is active.
The following permanent assignment applies to binary coding:
Code Override factor
00000000 0,00 ≙ 0%
00000001 0,01 ≙ 1%
00000010 0,02 ≙ 2%
00000011 0,03 ≙ 3%
00000100 0,04 ≙ 4%
. .
. .
. .
01100100 1,00 ≙ 100%
. .
. .
. .
11001000 2,00 ≙ 200%
With Gray coding, the override factors corresponding to the switch setting are entered in
machine data:
MD12070 OVR_FACTOR_SPIND_SPEED [n] (analysis of spindle override switch).
Activation of spindle override
If G33, G34, G35 active: Effective
(if the spindle is in position control mode, the
override switch may be activated)
If G63 active: Not effective
(the override is set to a fixed value of 100% in the
NC)
If G331, G332 active: Effective

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals