EasyManuals Logo

Siemens SINUMERIK 810D Function Manual

Siemens SINUMERIK 810D
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1778 background imageLoading...
Page #1778 background image
Supplementary conditions
3.2 Supplementary conditions for feedrate programming
Basic logic functions: Feeds (V1)
62 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Activation of the F values
Machine data:
MD22140 F_VALUES_ACTIVE_AFTER_RESET (F function active via RESET)
can be used to define whether the following most recently programmed F values are to
remain active following a RESET.
Programmed path feedrate: F=...
Programmed feedrate change for path feedrate: OVR=...
Programmed positioning feedrate: FA=...
Programmed feedrate change for positioning feedrate: OVRA[U]=...
For more detailed information about syntax, please see:
References:
/PG/ Programming Guide, Fundamentals
Position spindle
If G95,G96,G961,G97,G971,G33,G34,G35 is active, spindle positioning should not be
performed, because the derived path feedrate following spindle positioning = 0.
⇒ If the programmed axis position has not yet been reached, the block cannot be completed.

Table of Contents

Other manuals for Siemens SINUMERIK 810D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 810D and is the answer not in the manual?

Siemens SINUMERIK 810D Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 810D
CategoryControl Unit
LanguageEnglish

Related product manuals