Detailed description
2.7 Program operation mode
Basic logic functions: Mode group, channel, program operation, reset response (K1)
140 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
User ASUB
User routine protection level
If a user-defined routine is to be used, i.e., if there is a value not equal to 0 in
MD11610 $MN_ASUP_EDITABLE, then a protection level can be defined for the user-
specific routine _N_ASUP_SPF. The protection level can be set to values between 0 and 7
and must be entered in It must be specified in MD11612
$MN_ASUP_EDIT_PROTECTION_LEVEL (protection level of the user-specific ASUP
program. For further information about protection levels, refer to:
References:
/IADC/ Commissioning Manual; Protection Level Concept
Single-block processing
Bit 0 in machine data MD10702 $MN_IGNORE_SINGLEBLOCK_MASK (prevent single
block stop) determines whether internal ASUPs or the described user ASUPs are to be
executed without interruption after every block even when single-block processing is
selected:
Bit 0 set: Internal ASUBs are not stopped in any block.
Bit 0 not set Internal ASUBs are stopped in every block.
Danger
The machine manufacturer is responsible for the contents of ASUB routines used to replace
ASUP.SYF supplied by Siemens.