Step 1-D: Mounting the Straps for Direct-X Mode
A. Roughly Locate the Keepers on the horizontal plane of
the pipe. See Fig 1-9 and 1-10.
B. Using the Mylar material provided, make a template.
Tightly wrap the Mylar strip around the pipe and overlap
the ends. Cut off any excess. Temporarily tape the end
together. Mark the template with a marker where the
ends overlap. See Fig 1-11 and -1-12.
C. Remove the template. Align the mark with the other end
of the template and fold the Mylar while maintaining
alignment. Mark the fold crease with a marker.
(Note: If
you lay the template out on a table you will observe that
the distance between marks is half the actual
circumference of the pipe).
See Fig 1-13 and 1-14.
D. Reinstall the template. Locate it next to one of the most
outer strap locations. Align the marks of the template to
the horizontal plane of the pipe. Now align the keepers,
on center, with the marks on the template. See Fig 1-15
and 1-16.
(Note: It is important to maintain alignment of
this set of keepers throughout the remaining process. This
is the reference point when mounting the housings and
aligning and manipulating the remaining Keepers.)
Continue to Step 2.
Screw Lock
Buckle
Keepers
Locate the
keepers along
the horizontal
plane of the pipe
Fi
1-9 Fi
1-10
Fi
1-11 Fi
1-12
Fi
1-13
Fi
1-14 Fi
1-15 Fi
1-16
Mark
Align and
Fold
Distance is half of
circumference
On center
with marks
Pa
e 4 of 9
1012WS-1-7 Rev B
Mark the
Fold
Crease