EasyManua.ls Logo

Siemens SITRANS FUG1010 IP65 NEMA 4X - Page 244

Siemens SITRANS FUG1010 IP65 NEMA 4X
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pa
g
e 8 of 9
1012WS-1-7 Rev B
This photo shows what
a final installation
should look like. Only
one path is represented
here.
Tack Weld outer
ends of each
bracket, then
remove strap
Fi
g
4-1
Do not weld
this space
Fully weld all
locations.
Fi
g
4-2
Tack Weld center
support, then
remove strap
Fi
g
4-3
Step 4: (Optional) Weld assembly to pipe. If you desire,
you may weld the assembly to the pipe.
Considerations:
1. It is recommended you remove the transducers prior
to welding.
2. Removal of the side plates may be required in some
situations where the gap between the pipe and the
enclosure is diminished due to a large pipe diameter.
Retain all hardware.
Procedure:
A. While strap is in place, Tack Weld at the outer ends of
each bracket as shown in Fig 4-1.
B. Tack weld the center support. See Fig 4-2
C.
IMPORTANT: Do not weld the center of the bracket.
The space is necessary for maintaining proper
operation.
D. Remove the straps and fully weld all locations. See Fig
4-3.
E. Reassemble if side plates were removed.
F. Reinstall transducers per Step 3.
Note: Bracket Material is Type 316 Stainless Steel, Suitable for
welding to both Stainless Steel and Carbon Steel pipes.
Continue to Step 5