EasyManua.ls Logo

Siemens SITRANS FUG1010 IP65 NEMA 4X - Page 245

Siemens SITRANS FUG1010 IP65 NEMA 4X
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step 5: Install Gasket Seal. Two people may be required
to perform this step.
The procedure below is a recommended process. Any suitable method for
achieving a snug inner ring is acceptable.
Follow Fig’s 5-1 to 5-12. Surfaces must be clean and dry. Clean away any
excess coupling compound. Do not allow any slack to occur in the gasket
throughout this step. It must remain tight at all times.
Gasket Must Remain
Clean and Free of Grease at all times. If the gasket should become
contaminated, remove and use acetone to clean.
The Idea here is to seal the exposed gap between the transducers
footprint and the pipe. Wrap the transducer footprint, twice, with the O-
ring gasket material provided, then tie to secure in place. The inner layer
performs the function of seal. The second outer layer protects and backs
up the first.
Install the Housing Covers and remove the spacer bar to complete this
procedure.
Pa
g
e 9 of 9
1012WS-1-7 Rev B
Temporarily
tie off this end
of gasket.
Loosen
other end of
gasket.
Feed the gasket
underneath the
shroud at the
front end of the
transducer.
Pull tight, then let
go to snap in
place.
Fi
g
5-5 Fi
g
5-6
Fi
g
5-7 Fi
g
5-8
Feed the gasket
underneath the
shroud at the
back end of the
transducer.
Pull tight, then let
go to snap in
place.
While keeping
tight, tie both
ends together
Make a
double
knot
Cut any excess
gasket material
Stuff gasket
underneath
transducer.
A
pply a small
amount of RTV to
prevent gasket
from loosening.
Fi
g
5-9 Fi
g
5-10
Fi
g
5-11 Fi
g
5-12
Fi
g
5-1
Feed the gasket
underneath the opening
in the shroud at the back
end of the transducer.
Pull both ends ti
g
h
t
Use any protruding
hardware to
temporarily tie off
one of the ends
while maintaining
pull on the other
Feed the gasket
underneath the
shroud at the
front end of the
transducer.
Pull tight, then let
go to snap in
place.
Fi
g
5-2
Fi
g
5-3 Fi
g
5-4
Maintain
pull

Table of Contents