Functional Description
AG06
Date: 07.02.2018 Art. No. 85674 Mod. status 055/18 Page 20 of 114
Delta Inch
Value range: -19999 … 99999
(see chapter 8: Parameter description Parameter no. 17)
Inpos mode
Selection:
: Position control to set point
: Position control Off and short circuit of all motor windings
: Position control Off and drive enable
(see chapter 8: Parameter description Parameter no. 26)
Inching mode 2 acceleration type
Selection:
: static acceleration
: incremental acceleration
(see chapter 8: Parameter description Parameter no. 31)
Stop mode inching 2
Selection:
: stop with maximum deceleration
: stop with programmed deceleration
(see chapter 8: Parameter description Parameter no. 25)
Inching 2 Offset
Value range: 10 - 100
(see chapter 8: Parameter description Parameter no. 30)
PIN change
Value range: 0 - 99999
(see chapter 8: Parameter description Parameter no. 48)
S commands
Selection:
: execute no S command
: Set all parameters to default
: Set standard parameters to default
: Set controller parameters to default
: Set display parameters to default
: Set bus parameters to default
: Calibration
: Delete error memory
Table 8: Options menu