EasyManua.ls Logo

SimCom SIM700C

SimCom SIM700C
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 100 2018-05-08
5.2.23 AT+CGNAPN Get Network APN in CAT-M Or NB-IOT
AT+CGNAPN Get Network APN in CAT-M Or NB-IOT
Test Command
AT+CGNAPN=?
Response
+CGNAPN: (list of supported <valid>s),<length>
OK
Execution
Command
AT+CGNAPN
Response
+CGNAPN: <valid>,<Network_APN>
OK
If failed:
+CME ERROR: <err>
Parameters
<valid>
0
The network did not sent APN parameter to UE.In the
case,<Network_APN> is NULL.
1 The network sent APN parameter to UE.
<length>
Max the length of <network_APN>.
<Network_APN>
String type.The network sends APN p
arameter to UE when UE
registers CAT-M or NB-
IOT network successfully.In
GSM,<Network_APN> always is NULL.
Parameter Saving
Mode
-
Max Response
Time
-
Reference Note
In CAT-M or NB-
IOT,after UE sending attach request message,If core
network responds att
ach accept message that includes APN
parameter,<Netwok_APN> is valid.
5.2.24 AT+CSDP Service Domain Preference
AT+CSDP Service Domain Preference
Test Command
AT+CSDP=?
Response
+CSDP: (list of supported <domain>s)
OK
Read Command
AT+CSDP?
Response
+CSDP: <domain>