EasyManua.ls Logo

SimCom SIM700C

SimCom SIM700C
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 212 2018-05-08
15.2.9 AT+CGNSCFG GNSS NMEA Out Configure
AT+CGNSCFG GNSS NMEA Out Configure
Test Command
AT+CGNSCFG=
?
Response
+CGNSCFG: (list of supported <mode>s )
OK
Parameters
See Write Command
Read Command
AT+CGNSCFG?
Response
TA returns the current status of configure
+CGNSCFG: <mode>
OK
Parameters
See Write Command
Write Command
AT+CGNSCFG=
<mode>
Response
OK
or
ERROR
Parameters
<mode> 0 Turn off GNSS NMEA data out put to USB’s NMEA port
when set AT+CGNSPWR=1/0 through UART
1 Turn on GNSS NMEA data out put to USB’s NMEA port
when set AT+CGNSPWR=1/0 through UART
2 Turn on GNSS NMEA data out put to UART3 port when
set AT+CGNSPWR=1/0
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference Note
This command only supported in UART port.
SIMCOM COMFIDENTIAL FILE

Table of Contents

Related product manuals