Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 51 2018-05-08
<data> Information which shall be written to the SIM (hex-decimal
character format)
<sw1>,<sw2> Integer type, range 0 - 255
Status information from the SIM about the execution of the
actual Command. These parameters are delivered to the TE in
both cases, on successful or failed execution of the Command;
refer GSM 11.11.
<response> Response of a successful completion of the Command
previously issued (hexadecimal character format)
Mode
NO_SAVE
Time
-
Reference
3GPP TS 27.007
GSM 11.11
Note
3.2.16 AT+CSQ Signal Quality Report
AT+CSQ Signal Quality Report
Test Command
AT+CSQ=?
Response
+CSQ: (list of supported <rssi>s),(list of supported <ber>s)
Execution
Command
AT+CSQ
Response
+CSQ: <rssi>,<ber>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Execution Command returns received signal strength indication <rssi>
and channel bit error rate <ber> from the ME. Test Command returns
values supported by the TA.
Parameters
<rssi>
0 -115 dBm or less
1 -111 dBm
2...30 -110... -54 dBm
31 -52 dBm or greater
99 not known or not detectable
<ber> (in percent):
0...7 As RXQUAL values in the table in GSM 05.08 [20]
subclause 7.2.4