Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 57 2018-05-08
<bcs> Charge status
0 ME is not charging
1 ME is charging
2 Charging has finished
<bcl> Battery connection level
1...100 battery has 1-100 percent of capacity remaining
vent
<voltage> Battery voltage(mV)
Mode
NO_SAVE
-
Reference
3GPP TS 27.007
[13]
Note
3.2.23 AT+CUSD Unstructured Supplementary Service Data
AT+CUSD Unstructured Supplementary Service Data
Test Command
AT+CUSD=?
Response
+CUSD: (list of supported <n>s)
OK
Parameters
See Write Command
Read Command
AT+CUSD?
Response
+CUSD: <n>
OK
Parameters
See Write Command
Write Command
AT+CUSD=<n>,
<str>,<dcs>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<n> A numeric parameter which indicates control of the unstructured
supplementary service data
0 disable the result code presentation in the TE
1 enable the result code presentation in the TE
2 cancel session (not applicable to read Command response)
<str> String type (string should be included in quotation marks)
USSD-string