AT+FTPSIZE
Response
If successed:
OK
+FTPSIZE: 1,0,<size>
If failed:
OK
+FTPSIZE: 1,<error>,0
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<error> See "AT+FTPGET"
<size> The file size. Unit: byte
Parameter Saving
Mode
NO_SAVE
Max Response
Time
75 seconds(In case no response is received from server)
Reference
Note
The file is specified by the "AT+FTPGETNAME"
and
"AT+FTPGETPATH" commands.