SIM7000 Series_AT Command Manual_V1.03 20 2018-05-08
<value> 0 Echo mode off
1 Echo mode on
Parameter Saving
Mode
Max Response
Time
-
Reference
V.25ter
Note
2.2.4 ATH Disconnect Existing Connection
ATH Disconnect Existing Connection
Execution
Command
ATH
Response
Disconnect existing call by local TE from Command line and terminate call
OK
Note: OK is issued after circuit 109(DCD) is turned off, if it was previously
on.
Parameter Saving
Mode
NO_SAVE
Max
Response
Time
20s
Reference
V.25ter
Note
2.2.5 ATI Display Product Identification Information
Execution
Command
ATI
Response
TA issues product information text
Example:
SIM7000 R1351
OK
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference
V.25ter
Note