Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 101 2018-05-08
Parameters
See Write Command
Write Command
AT+CSDP=<do
main>
Response
OK
If failed:
+CME ERROR: <err>
Parameters
<domain>
0 CS(Circuit Switched Domain) ONLY
1 PS(Packet Switched Domain) ONLY
2 CS(Circuit Switched Domain) + PS(Packet Switched Domain)
Mode
AUTO_SAVE_REBOOT
Time
-
5.2.25 AT+MCELLLOCK Lock the special CAT-M cell
AT+MCELLLOCK Lock the special CAT-M cell
Test Command
AT+MCELLLO
CK=?
Response
+MCELLLOCK: (0,1),(0-65535),(0-503)
OK
Read Command
AT+MCELLLO
CK?
Response
+MCELLLOCK: <mode>[,<earfcn>,<pci>]
OK
Parameters
See Write Command
Write Command
AT+MCELLLO
CK=<mode>[,<e
arfcn>,<pci>]
Response
OK
If failed:
+CME ERROR: <err>
Parameter
<mode> 0 Unlock
1 Lock
<earfcn> A number in the range 0-
65535 representing the EARFCN
to search
<pci> A number in the range 0-503 representing the Physical Cell
ID to search