SIM7000 Series_AT Command Manual_V1.03 143 2018-05-08
OK
Parameters
See Write Command
Write Command
AT+CIPCCFG=
<NmRetry>,<Wa
itTm>,<SendSz>,
<esc>[,<Rxmode
>,<RxSize>,<Rxt
imer>]
Response
OK
ERROR
Parameters
<NmRetry> Number of retries to be made for an IP packet.Default
value is 5.
<WaitTm> Number of 100ms intervals to wait for serial input before
sending the packet. Default value is 2.
<SendSz> Size in bytes of data block to be received from serial port
before sending. Default value is 1024.
<esc> Whether turn on the escape sequence, default is TRUE.
0 Turn off the escape sequence
1 Turn on the escape sequence
<Rxmode>
Whether to set time interval during output data from serial
port.
0 output data to serial port without interval
1 output data to serial port within <Rxtimer> interval
.
<RxSize> Output data length for each time. Default value is 1460.
<Rxtimer> Time interval (ms) to wait for serial port to output data
again. Default value: 50ms
Parameter Saving
Mode
NO_SAVE
Max
Response
Time
-
Reference
Note
This command will be effective only in single connection mode
(+CIPMUX=0)
8.2.25 AT+CIPSHOWTP Display Transfer Protocol in IP Head When Received Data
AT+CIPSHOWTP Display Transfer Protocol in IP Head When Received Data
Test Command
AT+CIPSHOWTP
=?
Response
+CIPSHOWTP: (list of supported <mode>s)
OK
Parameters
See Write Command
Read Command
AT+CIPSHOWTP
Response
+CIPSHOWTP: <mode>
SIMCOM COMFIDENTIAL FILE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM700C and is the answer not in the manual?

SimCom SIM700C Specifications

General IconGeneral
BrandSimCom
ModelSIM700C
CategoryControl Unit
LanguageEnglish

Related product manuals