EasyManuals Logo

SimCom SIM700C User Manual

SimCom SIM700C
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #172 background imageLoading...
Page #172 background image
Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 172 2018-05-08
Write Command
AT+FTPUN=<va
lue>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<value> Alphanumeric ASCII text string up to 49 characters.
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference
Note
11.2.9 AT+FTPPW Set FTP Password
AT+FTPPW Set FTP Password
Test Command
AT+FTPPW=?
Response
OK
Parameters
See Write Command
Read Command
AT+FTPPW?
Response
+FTPPW: <value>
OK
Parameters
See Write Command
Write Command
AT+FTPPW=<v
alue>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<value> Alphanumeric ASCII text string up to 49 characters.
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference
Note
SIMCOM COMFIDENTIAL FILE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM700C and is the answer not in the manual?

SimCom SIM700C Specifications

General IconGeneral
BrandSimCom
ModelSIM700C
CategoryControl Unit
LanguageEnglish

Related product manuals