SIM7000 Series_AT Command Manual_V1.03 172 2018-05-08
Write Command
AT+FTPUN=<va
lue>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<value> Alphanumeric ASCII text string up to 49 characters.
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference
Note
11.2.9 AT+FTPPW Set FTP Password
AT+FTPPW Set FTP Password
Test Command
AT+FTPPW=?
Response
OK
Parameters
See Write Command
Read Command
AT+FTPPW?
Response
+FTPPW: <value>
OK
Parameters
See Write Command
Write Command
AT+FTPPW=<v
alue>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<value> Alphanumeric ASCII text string up to 49 characters.
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference
Note