SIM7000 Series_AT Command Manual_V1.03 97 2018-05-08
Table 10.5.163a/3GPP TS 24.008. See also 3GPP TS 23.682 [149]
and 3GPP TS 23.401 [82]. The default value, if availa
ble, is
manufacturer specific.
<Requested_Active-Time>
String type; one byte in an 8 bit format. Requested
Active Time
value (T3324) to be allocated to the UE
. The requested Active Time
value is coded as one byte (octet 3) of the GPRS Timer
2
information e
lement coded as bit format (e.g. "00100100" equals 4
minutes). For the coding and the value range, see the GPRS Timer
2
IE in 3GPP TS 24.008 [8] Table 10.5.163/3GPP TS
24.008. See also
3GPP TS 23.682 [149], 3GPP TS 23.060 [47]
and
3GPP TS 23.401 [82]. The
default value, if available, is
manufacturer specific.
Parameter Saving
Mode
AUTO_SAVE
Max Response
Time
-
Reference
Note
5.2.21 AT+CEDRXS Entended-DRX Setting
AT+CEDRXS Entended-DRX Setting
Test Command
AT+CEDRXS=?
Response
+CEDRXS: (
list of supported
<n>s),<AcT-type>,<Requested_eDRX_value>
OK
Read Command
AT+CEDRXS?
Response
+CEDRXS: <AcT-type>,<Requested_eDRX_value>
OK
Parameters
See Write Command
Write Command
AT+CEDRXS=<
n>,<AcT-type>,<
Requested_eDR
X_value>
Response
OK
If failed:
+CME ERROR: <err>
Parameters
<n>
0 Disable the use of eDRX
1 Enable the use of eDRX
2 Enable the use of eDRX and auto report
3 Disable the use of eDRX(Reserved)
SIMCOM COMFIDENTIAL FILE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM700C and is the answer not in the manual?

SimCom SIM700C Specifications

General IconGeneral
BrandSimCom
ModelSIM700C
CategoryControl Unit
LanguageEnglish

Related product manuals