SIM7000 Series_AT Command Manual_V1.03 162 2018-05-08
10 AT Commands for PING Application
SIM7000 series modules provide PING AT command is as follows:
10.1 Overview
Command Description
AT+CIPPING
PING Request
AT+CIPCTL Set the Mode When Receiving an IP Packet
AT+CIPFLT Set the Rules of IP Filter
10.2 Detailed Descriptions of Commands
10.2.1 AT+CIPPING PING Request
AT+CIPPING
PING Request
Test Command
AT+CIPPING=?
Response
+CIPPING: (list of supported <retryNum>s),(list of supported
<dataLen>s),(list of supported <timeout>s),(list of supported <ttl>s)
OK
Parameters
See Write Command
Read Command
AT+CIPPING?
Response
+CIPPING: <retryNum>,<dataLen>,<timeout>,<ttl>
OK
Parameters
See Write Command
Write Command
AT+CIPPING=<I
Paddr>[,<retryN
um>[,<dataLen>[
,<timeout>,<ttl>]]
]
Response
+CIPPING: <replyId>,<Ip Address>,<replyTime>,<ttl>[<CR><LF>
+CIPPING: <replyId>,<Ip Address>,<replyTime>,<ttl>[...]]
OK
or
ERROR
or
+CME ERROR: <err>