EasyManua.ls Logo

SimCom SIM700C

SimCom SIM700C
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 178 2018-05-08
Time
Reference
Note
When "+FTPPUT: 1,1,<maxlength>"
is shown, then use
"AT+FTPPUT=2, <reqlength>" to write data.
11.2.16 AT+FTPDELE Delete Specified File in FTP Server
Test Command
AT+FTPDELE=?
Response
OK
Parameters
See Execution Command
Execution
Command
AT+FTPDELE
Response
If successed:
OK
+FTPDELE: 1,0
If failed:
OK
+FTPDELE: 1,<error>
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<error> See "AT+FTPGET"
Parameter Saving
Mode
NO_SAVE
Max Response
Time
75 seconds(In case no response is received from server)
Reference
Note
The file to be deleted is specified by the "AT+FTPGETNAME"
and
"AT+FTPGETPATH" commands.
11.2.17 AT+FTPSIZE Get the Size of Specified File in FTP Server
AT+FTPSIZE Get the Size of Specified File in FTP Server
Test Command
AT+FTPSIZE=?
Response
OK
SIMCOM COMFIDENTIAL FILE

Table of Contents