SIM7000 Series_AT Command Manual_V1.03 194 2018-05-08
Write Command
AT+MIPLOPEN=
<ref>,<lifetime>,<p
aram>
Response
OK
Parameters
<ref> Config id
<lifetime> Lifetime to update automatically
<param> Reserved
Parameter Saving
Mode
NO_SAVE
Max Response Time -
Reference Note
13.2.4 AT+MIPLADDOBJ Add object
AT+MIPLADDOBJ Add object
Test Command
AT+MIPLADDOB
J=?
Response
+MIPLADDOBJ:
<ref>,<objectid>,<instancecount>,<instanceBitmap>,<attributeCou
nt>,<actionCount>
OK
Parameters
See Write Command
Write Command
AT+MIPLADDOB
J=<ref>,<objectid>
,<instancecount>,<i
nstanceBitmap>,<a
ttributeCount>,<ac
tionCount>
Response
OK
Parameters
<ref> Config id
<objectid> Object id
<instancecount> Count of instance
<instanceBitmap> Bitmap of instance
<attributeCount> Count of attribute resource
<actionCount> Count of action resource
Parameter Saving
Mode
NO_SAVE
Max Response Time -
Reference Note
13.2.5 AT+MIPLDELOBJ Delete Object
Test Command
AT+MIPLDELOB
J=?
Response
+MIPLDELOBJ: <ref>,<objectid>
OK