Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 195 2018-05-08
Parameters
See Write Command
Write Command
AT+MIPLDELOB
J=<ref>,<objectid>
Response
OK
Parameters
<ref> Config id
<object> Object id
Parameter Saving
Mode
NO_SAVE
Max Response Time -
Reference
Note
13.2.6 AT+MIPLCLOSE Disconnect to OneNet
AT+MIPLCLOSE Disconnect to OneNet
Test Command
AT+MIPLCLOSE
=?
Response
+MIPLCLOSE: <ref>
OK
Parameters
See Write Command
Write Command
AT+MIPLCLOSE
=<ref>
Response
OK
Parameters
<ref> Config id
Parameter Saving
Mode
NO_SAVE
Max Response Time -
Reference
Note
13.2.7 AT+MIPLNOTIFY Notify data to OneNet
Test Command
AT+MIPLNOTIFY
=?
Response
+MIPLNOTIFY:
<ref>,<msgid>,<objectid>,<instanceid>,<resourceid>,<valuetype>,
<len>,<value>,<index>,<flag>[,<ackid>]
OK
Parameters