EasyManua.ls Logo

SimCom SIM700C

SimCom SIM700C
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 158 2018-05-08
If<byte_size> is bigger than the data size received, module will only return
actual data size.
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<data> Data from HTTP server or user input.
<start_address> The starting point for data output.
0-319488 (bytes)
<byte_size> The length for data output.
1-319488 (bytes)
<data_len> The actual length for data output.
Execution
Command
AT+HTTPREA
D
Response
+HTTPREAD: <date_len>
<data>
OK
Read all data when AT+HTTPACTION=0 or AT+HTTPDATA is executed.
If error is related to ME functionality:
+CME ERROR: <err>
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference
Note
9.2.7 AT+HTTPSTATUS Read HTTP Status
AT+HTTPSTATUS Read HTTP Status
Test Command
AT+HTTPSTAT
US=?
Response
OK
Read Command
AT+HTTPSTAT
US?
Response
+HTTPSTATUS: <mode>,<status>,<finish>,<remain>
OK
If error is related to ME functionality:
+CME ERROR: <err>
SIMCOM COMFIDENTIAL FILE

Table of Contents

Related product manuals