EasyManua.ls Logo

SimCom SIM700C

SimCom SIM700C
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 48 2018-05-08
3.2.13 AT+CRC Set Cellular Result Codes for Incoming Call Indication
AT+CRC Set Cellular Result Codes for Incoming Call Indication
Test Command
AT+CRC=?
Response
+CRC: (list of supported <mode>s)
OK
Parameters
See Write Command
Read Command
AT+CRC?
Response
+CRC: <mode>
OK
Parameters
See Write Command
Write Command
AT+CRC=[<mod
e>]
Response
TA controls whether or not the extended format of incoming call
indication is used.
OK
Parameters
<mode> 0 Disable extended format
1 Enable extended format
Omitted Use previous value
Unsolicited Result Code
When enabled, an incoming call is indicated to the TE with unsolicited
result code +CRING: <type> instead of the normal RING.
Parameters
<type> ASYNC Asynchronous transparent
SYNC Synchronous transparent
REL ASYNC Asynchronous non-transparent
REL SYNC Synchronous non-transparent
FAX Facsimile
VOICE Voice
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference
3GPP TS 27.007
[13]
Note
SIMCOM COMFIDENTIAL FILE

Table of Contents

Related product manuals