SIM7000 Series_AT Command Manual_V1.03 48 2018-05-08
3.2.13 AT+CRC Set Cellular Result Codes for Incoming Call Indication
AT+CRC Set Cellular Result Codes for Incoming Call Indication
Test Command
AT+CRC=?
Response
+CRC: (list of supported <mode>s)
OK
Parameters
See Write Command
Read Command
AT+CRC?
Response
+CRC: <mode>
OK
Parameters
See Write Command
Write Command
AT+CRC=[<mod
e>]
Response
TA controls whether or not the extended format of incoming call
indication is used.
OK
Parameters
<mode> 0 Disable extended format
1 Enable extended format
Omitted Use previous value
Unsolicited Result Code
When enabled, an incoming call is indicated to the TE with unsolicited
result code +CRING: <type> instead of the normal RING.
Parameters
<type> ASYNC Asynchronous transparent
SYNC Synchronous transparent
REL ASYNC Asynchronous non-transparent
REL SYNC Synchronous non-transparent
FAX Facsimile
VOICE Voice
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference
3GPP TS 27.007
[13]
Note
SIMCOM COMFIDENTIAL FILE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM700C and is the answer not in the manual?

SimCom SIM700C Specifications

General IconGeneral
BrandSimCom
ModelSIM700C
CategoryControl Unit
LanguageEnglish

Related product manuals