EasyManuals Logo

SimCom SIM700C User Manual

SimCom SIM700C
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #213 background imageLoading...
Page #213 background image
Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 213 2018-05-08
15.2.10 AT+CGNSTST GNSS NMEA Data Out Put To At Port
AT+CGNSTST GNSS NMEA Data Out Put To At Port
Test Command
AT+CGNSTST=
?
Response
+CGNSTST: (0-1), (1-255)
OK
Parameters
See Write Command
Read Command
AT+CGNSTST?
Response
TA returns the current status of configure
+CGNSTST: <TST>
OK
Parameters
See Write Command
Write Command
AT+CGNSTST=
<TST>[,<cont>]
Response
OK
or
ERROR
Parameters
<TST> 0 Turn off GNSS NMEA data out put to AT port
1 Turn on GNSS NMEA data out put to AT port
<cont> 1-255 the number of NMEA data package
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference
SIMCOM COMFIDENTIAL FILE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM700C and is the answer not in the manual?

SimCom SIM700C Specifications

General IconGeneral
BrandSimCom
ModelSIM700C
CategoryControl Unit
LanguageEnglish

Related product manuals