Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 163 2018-05-08
Parameters
<IPaddr> Address of the remote host, string type. This
parameter can be either:
- IP address in the format: "xxx.xxx.xxx.xxx"
- Host name solved by a DNS query
<retryNum> The number of Ping Echo Requset to send
1-100 Default: 4
<dataLen> The length of Ping Echo Request data
0-1024 Default: 8
<timeout> The timeout, in units of 100 ms, waiting for a single
Echo Reply
1-600 Default: 100(10 seconds)
<ttl> Time to live
1-255 Default: 64
<replyId> Echo Reply number
<IP Address> IP Address of the remote host
<replyTime> Time, in ms, required to receive the
response
Mode
NO_SAVE
Time
-
Reference Note
Before sending PING Request the GPRS context must be activated.
When the Echo Request timeout expires (no reply received on time),
the response will contains <replyTime> setting to 600 and <ttl>
setting to 255.
When executing this command, if PDP context is deactivated for
some reasons, such as out of service, etc.the "+PDP: DEACT"
is reported and the command will end immediately.
If executing the command in NB-IOT network,please config
<timeout> to 300(30 second).For example:
AT+CIPPING="www.google.cn",4,8,300,64
10.2.2 AT+CIPCTL Set the Mode When Receiving an IP Packet
AT+CIPCTL Set the Mode When Receiving an IP Packet
Test Command
AT+CIPCTL=?
Response
+CIPCTL: (list of supported <mode>s)
OK
Parameters
See Write Command