<AcT-type>
4 CAT-M
5 NB-IoT
<Requested_eDRX_value> Requested eDRX value. 4 bit format.
"0000"-"1111"
Parameter Saving
Mode
AUTO_SAVE
Max Response
Time
-
Reference Note
The Requested_eDRX_value
is the value of cycle length, separately
means
5.12,10.24,20.48,40.96,61.44,81.92,102.40,122.88,143.36,163.84,327.
68,655.36,1310.72,2621.44,5242.88,10485.76.(seconds)
5.2.22 AT+CPSI Inquiring UE system information
AT+CPSI Inquiring UE system information
Test Command
AT+CPSI=?
Response
OK
Read Command
AT+CPSI?
If camping on a gsm cell:
+CPSI: <System Mode>,<Operation Mode>,<MCC>-<MNC>,<LA
C>,<Cell ID>,<Absolute RF Ch Num>,<RxLev>,<Track LO Adjus
t>,<C1-C2>
OK
If camping on a CAT-M or NB-IOT cell:
+CPSI: <System Mode>,<Operation Mode>,<MCC>-<MNC>,<TAC>
,<SCellID>,<PCellID>,<Frequency Band>,<earfcn>,<dlbw>,<ulbw>,<
RSRQ>,<RSRP>,<RSSI>,<RSSNR>
OK
If no service:
+CPSI: NO SERVICE,Online
OK
If failed:
+CME ERROR: <err>
Parameters
<System Mode> System mode.
"NO SERVICE"
"GSM"
"LTE CAT-M1"
SIMCOM COMFIDENTIAL FILE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM700C and is the answer not in the manual?

SimCom SIM700C Specifications

General IconGeneral
BrandSimCom
ModelSIM700C
CategoryControl Unit
LanguageEnglish

Related product manuals