EasyManua.ls Logo

SimCom SIM700C

SimCom SIM700C
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 149 2018-05-08
8.2.30 AT+CIPSENDHEX Set CIPSEND Data Format to Hex
AT+CIPSENDHEX Set CIPSEND Data Format to HEX
Test Command
AT+CIPSENDH
EX=?
Response
+ CIPSENDHEX: (0,1)
OK
Parameters
See Write Command
Write Command
AT+CIPSENDH
EX=<mode>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<mode> 0 The default format of output data in AT+CIPSEND.
1 Set the input data in HEX format when using CIPSEND
command to send data.
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference Note
8.2.31 AT+CIPHEXS Set Output-data Format with suffix
Test Command
AT+CIPHEXS=?
Response
+CIPHEXS: (list of supported <mode>s)
OK
Parameters
See Write Command
Write Command
AT+CIPHEXS=
<mode>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<mode> 0 The default format of output data
1 Set the output data with suffix "0d 0a"
2 Set the output data in HEX format with suffix "0d 0a".
Parameter Saving
Mode
NO_SAVE
SIMCOM COMFIDENTIAL FILE

Table of Contents

Related product manuals