8.2.30 AT+CIPSENDHEX Set CIPSEND Data Format to Hex
AT+CIPSENDHEX Set CIPSEND Data Format to HEX
Test Command
AT+CIPSENDH
EX=?
Response
+ CIPSENDHEX: (0,1)
Parameters
See Write Command
Write Command
AT+CIPSENDH
EX=<mode>
Response
OK
If error is related to ME functionality:
Parameters
<mode> 0 The default format of output data in AT+CIPSEND.
1 Set the input data in HEX format when using CIPSEND
command to send data.
Mode
NO_SAVE
Time
-
Reference Note
8.2.31 AT+CIPHEXS Set Output-data Format with suffix
AT+CIPHEXS Set Output-data Format with suffix
Test Command
AT+CIPHEXS=?
Response
+CIPHEXS: (list of supported <mode>s)
Parameters
See Write Command
Write Command
AT+CIPHEXS=
<mode>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<mode> 0 The default format of output data
1 Set the output data with suffix "0d 0a"
2 Set the output data in HEX format with suffix "0d 0a".