15. Technical data
KFG KFGS KFGL KFGC
Continuation of Technical data
Description Value
12/24 VDC 90...264 VAC
Perm. operating temperature with spring return pump elements -25 °C to +70
°C
-25 °C to +60 °C
Perm. operating temperature with spring return pump elements -30 °C to +70
°C
-30 °C to +60 °C
Electrical values See Chapter 6, "General conditions for connections," page 41
Protection class according to DIN 40050, T9 IP56 IP56
Operating mode/ON-time according to VDE0530/ DIN 41756 S1
continuous
operation
Data universally applicable to KFG, KFGS; KFGL; KFGC
Max. back pressure
300 bar with spring return pump elements
350 bar with spring return pump elements
Max. Number of outlets (if less than 3 outlets are required,
close unneeded outlets with screw plugs)
3
Delivery rates[cm
3
/min]
KFG1.U1 = 2.5 KFG1.U2 = 1.8 KFG1.U3 = 1.3 KFG1.U4 = 0.8
KFG1.U0 = 5.0 at max. 200 bar
KFG1.U0-E at max. 250 bar
Lubricant
NLGI Grade 1 to 2 greases with EP additives, compatible with plastics,
NBR elastomers, copper and copper alloys
Flow pressure Up to max. 700 mbar