8. Commissioning
The reservoir unit described here functions
automatically. The lubricant transport in the
lubrication lines should, however, be subjected
to regular visual inspection.
The lubricant fill level in the lubricant reservoir,
if present, should likewise be subjected to reg-
ular visual inspection. If the lubricant fill level
is too low, lubricant needs to be added up to
the maximum mark as described in
Chapter
4.4.1.
Observe the instructions from the
machine manufacturer regarding the
lubricants that are to be used.
Warning!

appropriate device. Contaminated lubri-
cants can result in severe system mal-
function. The lubricant reservoir must

Warning!
Different lubricants cannot be mixed,
as mixing may result in damage and
necessitate costly and complicated
cleaning of the product/centralized
lubrication system.
It is recommended that an indication of
the lubricant in use be attached to the
lubricant reservoir in order to prevent
accidental mixing of lubricants.
8. Commissioning
8.1 General commissioning
Before the product is commissioned, all elec-
trical connections must be inspected.
The lubricant may only be fed without bubbles.
The lubricant reservoir, if present, must be
filled with clean lubricant without introducing
bubbles. The product is then operated until lu-
bricant without bubbles is discharged at all lu-
brication points.
The process of venting the centralized lubrica-
tion system can be facilitated by:
Opening the ends of the main pipes until
lubricant without bubbles is discharged.
Filling long pipe sections before connect-
ing to the lubrication points.