14. Operational and pump faults
KFGS
14.2.3 Fault types
Depending on the severity of the fault, the
control unit issues either a warning or a mal-
Fault types
Fault type Definition Display Example of fault Response by control unit
Malfunction A fault has occurred that affects
the proper functioning of the
lubrication system.
The lubrication points may
not be supplied with adequate
lubrication because a malfunc-
tion has affected the proper
functioning of the lubrication
system.
Malfunctions must always be
remedied immediately.
Insufficient number of piston
detector signals from a
lubrication segment during
the pump cycle time
Block operation up to con-
figured number of repetitions
- If the piston detector signal has
still not been received, the valve
is closed and a fault notification is
generated.
-LED lights up
Page 98