4.16 Note on the rating plate
The rating plate of pump units KFG and KFGS
displays important specifications such as type
designation and short material description (or
customer number).
To avoid loss of this data in case the rating
plate becomes illegible, these characteristics
should be entered in the following table.
Enter key data from rating plate in the
following table.
Type designation
Barcode
Power supply
Serial number
4.14 Progressive system ventilation
Fill pump with lubricant.
Remove main lines on unit.
Allow pump to run until lubricant without
bubbles is discharged at the straight con-
nector of the pump element.
Mount main lines.
Allow pump to run until grease can be seen
discharging at all lubrication points.
4.15 Single-line system ventilation
Fill pump with lubricant.
Remove main lines (pressure relief valve as
necessary) on unit.
Allow pump to run until lubricant without
bubbles is discharged at the straight con-
nector.
Mount main lines.
Remove screw plug or pressure switch at
end of main and branch lines.
Allow pump to run until air is no longer
discharged at the end of the line sections.
Mount screw plug or pressure switch.
Vent lubrication lines and lubrication points
and inspect for proper function.