14. Operational and pump faults
14. Operational and pump faults
KFG KFGS KFGL KFGC
14.1 Operational malfunctions
14.1.1 General information
The operator/operating personnel must perform
visual fill level control of the lubricant reservoir
at regular intervals. The control intervals de-
pend on the amount of lubricant required and
the pump's run time. The operator/operating
personnel must therefore determine the inter-
vals on their own based on the specific condi-
tions of usage.
If the reservoir has been emptied, the entire
system must be ventilated after refilling (see
Chapter 6, Assembly).
14.1.2 Malfunctions on pump units
Pump malfunctions
Fault
Possible cause Rectification
Pump Agitator in
grease reservoir does
not rotate during the
activated pump cycle
time
Mechanical damage, e.g.,
motor defective.
Low voltage
Electrical connection
interrupted
• Replace pump.
- Loosen main line at outlet of
pressure regulating valve
- Loosen electrical connection.
- Loosen three fastening screws.
- Remove defective pump.
- Mount new pump and connect
lubrication line and electrical
cable.
• Perform commissioning and
functional inspection.
• Be sure the interval and contact
times are correct.
• Check or replace
fuse.
• Check electrical connections.
• Check cable set for damage.