13. Maintenance and service
KFG KFGS KFGL KFGC
Maintenance work
Maintenance work Action Interval
KFG; KFGS; KFGL; KFGC
Check of fill level in lubricant
reservoir
Refill if necessary. Depends on planned lubricant consumption
Inspection of system com-
ponents (lubricant lines,
connection points, seals, etc.)
for leaks.
Parts that exhibit leaks must be replaced. Please contact
an SKF service office
After each refill of the lubricant reservoir or after
long operational pauses before commissioning the
system
Visual inspection of bearings'
lubrication
In case of insufficient bearing lubrication, a fault in the
lubrication system or incorrect system configuration is
the probable cause.
Observe the instructions contained in these operating
instructions. If necessary, please contact an SKF service
office.
In conjunction with lubrication reservoir filling.
KFGS; KFGL; KFGC
Check of basic function of
control unit and system
components
To inspect the basic functions, trigger an interim lubrica-
tion by pressing the
key or send the corresponding
CAN command.
After each lubrication reservoir filling
Inspection of electrical cables
for damage
Damaged cables must be replaced. Please contact an
SKF service office
After long operational pauses before commission-
ing the machine/vehicle
Inspection of electrical con-
nections and contacts for firm
attachment and corrosion
Tighten loose contacts. Clean any corroded electrical
contacts with a wire brush, then apply a small amount of
contact grease after installation
Whenever maintenance is performed, and at least
once every six months