127
10. Enter a car call to the top terminal landing send the car up
towards the UET magnet at Contract Speed (MAIN MENU | DEBUG
| ENTER CAR CALLS).
11. As the car passes the UET magnet it will get a F80:UETS
Overspeed” fault and perform an emergency stop.
12. When the car comes to a complete stop and the fault A64:
Stop No DZ appears on the screen, quickly switch the car to
Inspection (MR) before the controller resets and tries to correct
itself.
13. Record the position the car is currently stopped at from the
home screen of the LCD.
E-Stop Position: ____’ ____.____”
In spect ion (MR) DZ
.. [ | ]PI : 3 T-14
23 40 36’06.75
CMD: 0 FP M: 0
DZ MAG NET FLOOR ##
To p: 3 409 . 06
Bottom :34 03.06