19
BYPASS TERM LIMITS
(Check off box when complete)
Toggle the Inspection/Normal switch to the “INSP” position.
Set BYPASS TERM LIMITS to YES:
On the Smartrise Machine Room controller board, press the Left
Arrow (ESC) button several times to get to the MAIN SCREEN.
Press the Right Arrow to go to MAIN MENU. Use the Up / Down
Arrow keys and move the asterisk to SETUP and press the enter
key.
o
Use the Up / Down Arrow keys and move the asterisk to MISC
and press the enter key.
BYPASS TERM LIMITS should be the first item listed. If it’s not, use
the Up / Down Arrow keys and move the asterisk to BYPASS
TERM LIMITS and press the enter key.