211
Sets the position at which the counterweight will pass the car.
MAIN MENU | SETUP | ACCESS DIST TOP |
Sets the allowable distance the car is allowed to travel down on Top Access.
MAIN MENU | SETUP | ACCESS DIST BTM |
Sets the allowable distance the car is allowed to travel up on Bottom Access.
MAIN MENU | SETUP | PI LABELS|
This feature permits the user to label any landing to a 2 digit alpha-numeric or numeric configuration.
MAIN MENU | SETUP | REAL-TIME CLOCK|
TIME
This feature sets the internal clock time for fault identification.
DATE
This feature sets the internal clock date for fault identification.
MAIN MENU | SETUP | LOCAL INPUTS |
The feature allows the user to see if the Smartrise SRU is registering an input. The inputs are board
specific; For example, when looking on the Car Top SRU it will show just the Car Top inputs.
MAIN MENU | SETUP | LOCAL OUTPUTS |
The feature allows the user to see the programmed output configuration for any Smartrise SRU. For
example, if using the Machine Room SRU this would allow the user to see all programmed outputs on
the Machine Room Board.
MAIN MENU | SETUP | SECURITY |
ENABLE CC LOCKOUT
When enabled (Yes) input(s) will become actively monitored to secure all car calls. The input requires
a 24VC input from the security source.
TIMED LOCKOUT HC
When enabled (Yes) the controller will lock out all Hall Calls in the programmed time period below.
USE FLOOR CODES
When enabled (Yes) the user set codes for each floor are now active.
IND SRV OVERRIDES
When enabled (Yes) Independent Service will override all Car Call security specifications.
START TIME (M-F)
When timed Hall or Car call is enabled this parameter defines the time of the day Mon-Fri the
controller will start locking out the call.
STOP TIME (M-F)
When timed Hall or Car call is enabled this parameter defines the time of the day Mon-Fri the
controller will stop locking out the call.
START TIME (S-S)
When timed Hall or Car call is enabled this parameter defines the time of the day Sat-Sun the
controller will start locking out the call.
STOP TIME (S-S)
When timed Hall or Car call is enabled this parameter defines the time of the day Sat-Sun the
controller will stop locking out the call.
PER FLOOR OPTIONS
FLOOR # (F) 24/7
This parameter turns on security for the front door of Floor # for 24hrs/7days week.