212
FLOOR # (R) 24/7
This parameter turns on security for the rear door of Floor # for 24hrs/7days week.
FLOOR # (F) TIMED
This parameter turns on security for front door of Floor # based on time of day.
FLOOR # (R) TIMED
This parameter turns on security for rear door of Floor # based on time of day.
ACCESS CODE (F)
This parameter will set an access code to be used for accessing the front door of a security
enabled floor.
ACCESS CODE (R)
This parameter will set an access code to be used for accessing the rear door of a security
enabled floor.
MAIN MENU | SETUP | MISC |
BYPASS TERM LIMITS
When enabled (Yes) permits the controller to move above or below the bottom and top Door Zone
magnets on inspection only.
EMERGENCY POWER
When set to Yes the controller will monitor an Emergency Power input to determine when to initiate
emergency power operation.
MONITOR BPS
When set to Yes the controller will monitor the brake pick switch on the input it is wired to.
CAUTION! Setting this function to No will ignore the brake pick switch which could lead to a
dangerous situation, and possibly a fire if the brake doesn’t open and the car is still running.
BPS IS N.C.
Allows the user to change the input for the brake pick switch from normally open (NO) to normally
closed (NC).
NUM COP EXP BOARDS
This parameter defines how many extra COP boards the controller is expecting. This parameter is
only pertinent to specific applications.
HOLD WITH PICK
Not used for hydraulic applications
RESYNC START TIME
For hydraulic applications only. This parameter defines the time to initialize the jack re-synchronizing
command.
RESYNC DURATION
For hydraulic applications only. This parameter defines the duration the controller will remain in jack
re-synchronization.
SABBATH
Sets the car to automatically run to every floor, stop, and open the doors.
UP VALVE UL WHEN UH
This turns on the UPL valve when the UPH valve is actuated (Hydros Only).
MAIN MENU | SETUP | DEFAULT ALL |
Defaults all parameters to the conditions listed here. If DIP switch one is placed down in conjunction
with a default all critical values will be defaulted as well.
MAIN MENU | DEBUG |
ENTER CAR CALLS
Allows the user to input a car call from the Car Top or the Machine Room.