H6 Hybrid Inverter - Installation & Operation Guide
92
Copyright 2017 SolarCity Corporation. All rights reserved.
9.1.2 - Mechanical
The mechanical specifications of the SolarCity H6 inverter are:
• Height: 630mm (~24 7/8”) with wiring box and no ZigBee antenna; 400mm (15.75”)
without wiring box
• Width: 400mm (~15 3/4”)
• Depth: 196mm (~7 3/4”) without switch handle
• Weight: 28kg (~62lbs)
• Cooling: Natural convection
• AC Connectors: Spring clamp connectors (in wiring box)
• DC Connectors: Spring clamp connectors (in wiring box)
• Communication Interface: CAN (local) and ZigBee (external)
• Firmware Upgrade: ZigBee
• Display: Three (3) LEDs, two (2)-line LCD with 16 characters per line
• Enclosure Material: Die-cast aluminum
• Revenue Grade Meter: ANSI C12.1, 1% Class
9.1.3 - PV Input
The PV input specifications of the SolarCity H6 inverter are:
• Nominal Voltage: 380V
• Max. System Voltage: 570V
• MPPT Operating Voltage Range: 85V to 550V (120V startup)
• Full Power MPPT Voltage Range: 200V-480V
• Max. Allowed DC to AC ratio: 150%
• Max. Continuous Current: 19A per MPP channel
• Max. Short Circuit Current: 26A per MPP channel
• Integrated Manual DC Disconnect: 600V, 30A UL-listed switch
• MPP tracker/channels: two (2)
• Total input strings possible: four (4)
• Conduit Size: 2 x 3/4” (1x 3/4” optional)
• Wire Size: 8-12AWG supported