• The H6 inverter is factory configured with AC Grid charging disabled. It can only charge
from PV.
• The Grid charging setting is password-protected and cannot be modified by the end user.
• You can verify that the inverter has not grid charged by viewing the LCD display and
looking at the grid charging register.
5.9.4 - Rapid Shutdown (RSD)
The wiring box includes a Rapid Shutdown Master (Power Line Communication or PLC
Transmitter) that sends a simultaneous wireless PLC signal to the RSD boxes connected to all
of the strings in the PV array via the high-voltage DC lines connected to the PV+ and PV-
connections. The Rapid Shutdown Slaves (communication receivers) that receive these
wireless PLC signals are embedded in the RSD boxes on the roof. This RSD signal initiates a
rapid shutdown when triggered by the Fireman Switch located either beside the main panel
or by the DC Disconnect Switch. See
Figure 3-14
and
Figure 3-15
for mounting and operation,
respectively. See also
“PV Interface” on page 28
.
When the Fireman Switch is pressed or the DC Disconnect Switch is set to OFF, the DC
feeders between the SMART RSD device and the SolarCity H6 inverter becomes de-energized
below 30V, 8A, 240VA within less than ten (10) seconds. The SolarCity H6 inverter will not
export AC power to the grid or to protected home loads and also disables the battery pack at
the same time. Please see
“Fireman Switch and Rapid Shutdown” on page 42
for detailed
operation information.
5.9.5 - Dark-Start Feature
When there is no PV energy, no AC grid, and if the inverter and battery disconnects are in the
OFF positions, then you can restart the system by turning the inverter and battery pack
disconnects to the ON position, waiting for one (1) minute, and then pressing and holding
both the [UP] and [DOWN] buttons simultaneously for five (5) seconds. This operation causes
the SolarCity H6 inverter to send an ENABLE signal to the Battery Pack and come online
within eight (8) seconds. The system can turn on automatically if there is AC grid or PV
energy, or if the inverter and battery disconnects are in the ON position.