14. Replace the wiring box cover as described in
“Refit Wiring Box Cover” on page 60
.
15. Close the wiring box cover by tightening the four (4) screws.
16. Move the external AC disconnect / back-feed breaker in the main electrical panel to the
ON position.
17. Turn the DC Disconnect Switch to the ON position. If the battery pack includes a DC
disconnect, then turn that switch ON as well.
18. If needed, configure the network for the MAC address of the new ZigBee chip.
19. Verify that the ZigBee chip is communicating properly with the SolarCity server.
Verify that the SolarCity H6 inverter and battery pack are functioning normally.